Service 01 · ASCE/SEI 7-22 · Chapters 26–30

Wind loads, worked the way you would.

Every pressure zone, coefficient, and load case from ASCE 7-22 — computed step by step, shown in full, and rendered as an interactive 3D model you can turn in your hand — then exported as a report you can put straight in the project file.

Built and maintained by a licensed structural engineer.

3D gable building model, faces coloured by design pressure with arrows showing push and pull

Live output — every surface coloured by its design pressure, with the load direction shown. Rotate it in the app.

Coverage schedule

The cases your projects actually run

One tool across the whole wind scope — no jumping between spreadsheets for the sub-mode you happen to need today.

Reference System Cases covered
Ch. 27 MWFRS Directional procedure — enclosed, partially enclosed & partially open; flat, gable, hip, monoslope, arched and domed roofs; open buildings (monoslope, pitched, troughed).
Ch. 30 Components & Cladding General, multi-span, tall (h > 60 ft) incl. elevated soffit, open buildings, parapets, roof overhangs, attached canopies, silos & tanks, roof pavers.
Ch. 29 Appurtenances Solid freestanding signs & walls, chimneys / tanks / silos, open signs & single-plane frames, trussed towers.
§29.4.3–.5 Solar Rooftop panels, tilted and parallel to the roof, plus ground-mounted fixed-tilt arrays with dynamic gust effects.

Capabilities

Rigorous where it counts, quick everywhere else

The engine follows ASCE 7-22 to the letter. The workflow keeps you moving through it.

Reporting

Branded PDF output

Every calculation exports a clean report with inputs, results and code references — ready for the project file.

Transparency

Nothing is a black box

Each step shows the governing equation, the coefficients used, and every intermediate value behind the result.

Continuity

Projects that reopen

Organize work in a folder tree and reopen a whole session — every sub-mode — exactly where you left it.

Method

Strict ASCE 7-22

Closed-form coefficients where the Commentary provides them, with figure-rounded values available when you prefer.

Team

Seats you manage

Your firm admin adds or removes engineers as the team changes, within the seat count on your plan.

Access

Nothing to install

Runs in the browser, on any machine — office desktop or a laptop on site. No licence keys to chase.

The deliverable

The report is the product

Every run exports a report built for the project file — inputs echoed, every provision cited, pressure diagrams drawn, and the limits the code imposes checked and shown. This is the actual output for a sample gable warehouse, untouched.

Sample report page 1 — pressure diagrams and consolidated design pressures table
Sample report page 2 — design wind load cases and provisions applied
Download the sample report (PDF)

Pricing

Per engineer, billed to the firm

Full wind scope on every plan. Add or remove engineers anytime. Thirty days free. Tell us about your team and we’ll set up your trial — no card needed to start.

Monthly pay as you go
$35
per engineer / month
All sub-modes — MWFRS, C&C, Appurtenances, Solar
Unlimited projects and saved work
Branded PDF reports
Firm admin manages your team
Request a trial
Firm 10+ seats
Custom
let’s talk
Volume discount above 10 seats
Centralized billing
Onboarding help
Direct line for support
Contact us

Professional-use note. The Wind Load Calculator is a calculation aid implementing provisions of ASCE/SEI 7-22. It does not perform engineering services and is not a substitute for engineering judgment. The licensed engineer of record is solely responsible for verifying all inputs, outputs, applicability, and code compliance before any reliance or use.